1.09142

SODIUM HYDROXIDE SOLUTION C(NAOH) = 0.02 MOL/L (0.0

CAS Number: 1310-73-2
Nhóm sản phẩm
MÃ SẢN PHẨM Kích cỡ gói Sẵn có Giá Số lượng
Request a Bulk Order Kíểm Tra Còn Hàng

Thuộc tính

Thuộc tính
Description SODIUM HYDROXIDE SOLUTION C(NAOH) = 0.02 MOL/L (0.0
Yêu cầu giấy phép Not required
Kiểm tra hết hạn 12/31/9999 12:00:00 AM
Kiểm soát nhiệt độ 40
Hình thức vận chuyển DAS
Lĩnh vực sản phẩm 527

Mô tả

General description

Features and Benefits

Accreditation:
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.

Packaging

SKU-pack size numbers ending with a "3" are SmartChemicals with an RFID tag on the label for seamless data transfer to the instrument, e.g. xxxxxx1003 or xxxxxxx 4003. More information on www.sigmaaldrich.com/SmartChemicals

Analysis Note

Form liquid
Amount-of-substance concentration 0.01990 - 0.02010 mol/L
Measurement uncertainty ± 0.00006 mol/L
Traceability NIST SRM

The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is determined with standardized hydrochloric acid solution (article number 1.09060). The hydrochloric acid solution is standardized and traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 723 Tris(hydroxymethyl)aminomethane) by means of volumetric standard Tris(hydroxymethyl)aminomethane (article number 1.02408), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.

Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.

Legal Information

Titripur is a registered trademark of Merck KGaA, Darmstadt, Germany

THÔNG TIN AN TOÀN

Signal Word

RIDADRRIDADR

WGK Germany

Flash Point (F)

Flash Point (C)

Target Organs

Risk Statement

Cảnh cáo nguy cơ bổ sung

TÀI LIỆU

Chứng nhận phân tích View Sample COA
Chứng nhận xuất xứ

Hỗ Trợ Kỹ Thuật

Đội ngũ các nhà khoa học của chúng tôi có kinh nghiệm trong tất cả các lĩnh vực nghiên cứu bao gồm Khoa học Đời sống, Khoa học Vật liệu, Tổng hợp Hóa học, Sắc ký, Phân tích và nhiều lĩnh vực khác.